D11 Precision Low Drift Lload Cell Amplifier:
Load Cell Amplifier
Click here for PDF version of this page.
Features
- Terminals for 4 load cell inputs. A maximum of 8 (350ohm) cells can be powered with 10v DC excitation voltage
- ’Single Shot’ calibration - Fully independent gain and zero offset calibration adjustment by means of DIL switches and potentiometers
- Industry standard 4 - 20mA and 0 - 10v DC (max.) buffered outputs
- 240/110v, 50Hz supply, selectable by movable links
- Earthed signal ground-can be isolated by cutting a link
- Diecast aluminium IP65 enclosure. Access for cables via cable glands (7mm max. cable size) Dimensions: 260mm x 160mm x 90mm
Weight: 2.8kg
- Power supply 240v/110v, 50Hz + 10%-15% Link selectable
- Maximum excitation current 300mA
- Hysteresis +/-0.075% F.S. (Vin 0 to 10mV, Av 200)
- Excitation voltage =/- 5v DC =/- 0.2%
- Linearity =/-0.02% F.S. (Vin 0 to 10 mV, Av 200)
- Operating temperature range 0 to 50°C
- Current loop output: Load resistance RL 50R to 500R. Maximum offset voltage 30uV. Voltage drift o.75uV/°C. Non linearity 0.01% max. True two wire system 4 to 20mA